
Stand Type X-ray Wall Mounted X-ray
BCD Technology Co., Ltd.- Applicable Departments:Oral Surgery
- Certification:CE
- Material:Metal
- Product:Dental X-ray
- Transport Package:Standard Export Pack
- Specification:1pcs,carton
Base Info
- Model NO.:LTD-X5
- Trademark:LETY
- Origin:China
- Production Capacity:1000units,Month
Description
Parameters InstructionModel:RAY98(P) Frequency: 5OHz-60Hz Exposure Time Range: 0.04s-2.0s Tube Voltage:70kV±10% x-Tube: CANON D-045 Leak Emissivity: 1 meter 0.25mGy/h Tube Current: 2mA+-20% Anode Angle: 12.5° Machine Weight: 1.7kg Charge input Voltage: 100V-240V Focus: 0.4mm Relative Humidity: 30%RH~75%RH
Parameters InstructionPower Voltage:AC 220V Bulb Tube:TOSHIBA D- 045 Duty Cycle:1/30 Frequency:50/60Hz Ray Focal Spot:O.4mm Half Value Layer:65KV Maximum Power:110OVA Bulb Tube Voltage:65KV±10% lnherent Filtration:≥2.1mm Al Electricity:5A Anode Current:7mA±20% Leakage Radiation:1meter≤0.14mGy/h Fuse:10A Anode Angle:12.5° Time Of Exposure:0.01--2.0s




1. Strong analgesic effect and can greatly reduce the patient's pain and anxiety. 2. Sweety, non-respiratory tract irritation, patients are willing to accept. 3. Patients always remain sober, and cooperate initiatively and non-respiratory tract inhibition. 4. Easy to use, do not need special equipment and professional anesthetist. 5. The density and the flow of nitrous oxide and oxygen can be adjusted. 6. Can use in the pediatric extraction, without increasing respiratory secretions, without affecting on breathing, without muscle relaxant role; patients can breathe independently, the protection of the throat reflection is active, no reserves, you can go back immediately after operation, safeand reliable. 7. Hypertension patients use the oxide and oxygen inhalation device in the extraction, electrocardiogram, blood pressure, pulse, respiration, oxygen saturation are stable, no signs of arrhythmia and myocardial ischemia, no stress-induced hypertension response. 8. In the extraction of buried teeth, use the nitrous oxide inhalation analgesia and partial infiltration anesthesia, it can achieve perfect results; simple method, less cost, obvious effect. Maximum total flow:≥17L/min Precise flow: min 0.5L N2O: 0-70%; O2: 30%-100% Input pressure:50PSI±10% Input link: standard 5/8' DISS Patient output link:15/22mm Double mask scavenger: optional Bag tee:Emergency air valve Safe valve:automatic on/off N2O Compensation proportion: Adjustable in 0-17L/min when the mixed density is stable. O2 quick supplement: not less than 17L/min Configuration:Standard: Flow meter, bag tee, double mask scavenger, respiratory pipeline Optional: High-efficient HEPA filter, autoclavable mask, disposable mask, demand valve resuscitator






Dental Conscious Sedation System Nitrous Oxide Oxygen Sedation System dental anesthesiaIntroduction
Nitrous oxide sedation has been widely used in clinical practice for 160 years. When the patient is conscious, inhalation of proportionally mixed N2O and O2 is universally recognized as the safest, most effective and receptive way of sedation. It has remained as one of the most widely used anesthetics in both dental and medical applications

